STANDARD MACHINE DATA
Sale
= 0
Display Logo = 1
Price holding = 0
Key enter =
0
Fans stop =
1
Payment =
1 (executive)
DEVICE
Photo cell =
1 if vend detector is fitted
Elevator
= 0
Incup option = 0
Refrigerator = 1
60 prices cat. = 0
PROTECTED TIME
All parameters = 0
DATE TIME
Alter these parameters to set local time
|
TEMPERATURES
Tmin.
= 6
Tmax.
=10
Tall.
= 30
Demerg.
= 60
Dcomp.
= 15
LIGHTS
Set the time that internal lights go on and off to suit the site
PRICES
Create a price list (setting price 00 to 00)
LINK TO PRICES
Link the prices in the price list to individual spirals.
Unassigned spirals will be set to free vend
|
Setting Description
|
Default
value
|
Effect of
Standard value
|
Alternative
Value(s)
|
Effect of
Alternative
Value(s)
|
See
these pages for
more
detail
|
||||||
Sale
|
0
|
The coin system will
only accept money for a single purchases item and give change if
available
|
1
|
The coin system will accept a number of coins and allow
Multiple purchases
|
|
||||||
Display logo
|
1
|
The Manea logo will move across the LCD screen
|
0
|
The logo will
be static and
Data transmission is permitted
|
|
||||||
Price
holding
|
0
|
Prices for goods
are stored in the VMC
|
1
|
Prices for goods
are stored in
the coin system
|
|
||||||
Key enter
|
0
|
A purchase can be made without pressing the enter key
|
1
|
A purchase can only
be made after
confirming it
with the enter key
|
|
||||||
Fans stop
|
1
|
The evaporator fans
do not run continuously
|
0
|
The evaporator
fans run continuously
|
|
||||||
Payment
|
1
|
The payment system is set up for Free Vend
Executive
Parallel
PC
MDB
|
0
1
2
3
4
|
0 FREE VEND
This can be used for free operation of the machine or to test the
machine.
1 EXECUTIVE Sets the operation of the machine to Mars
Executive protocol
2 Parallel Sets the operation of the coin system
in parallel mode
3 PC Allows payments to be controlled by a PC
based system
4 MDB Sets the operation of the machine to MDB Protocol.
|
|
||||||
Device
|
|
|
|
|
|
||||||
Photo cell
|
1
|
Vend detector enabled
|
0
|
Vend detector
disabled
|
|
||||||
Elevator
|
0
|
Lift option disabled
|
1
|
Lift option enabled
|
|
||||||
In cup
|
0
|
In cup drinks system
|
1
|
In cup drinks system
|
|
||||||
Refrigerator
|
1
|
Refrigeration On
|
0
|
Refrigeration Off
|
|
||||||
60 price
|
0
|
Standard 20 price list
|
1
|
Up to 60 different prices can be set
|
|
||||||
|
|
|
|
|
|
||||||
Protected
Time all parameters set
|
0
|
|
|
|
|
||||||
|
|
|
|
|
|
||||||
Date/Time
|
Various
|
Set to local time
|
|
|
|
||||||
|
|
|
|
|
|
||||||
Temperature
|
|
|
|
|
|
||||||
Tin
|
6
|
|
|
|
|
||||||
Tax
|
10
|
|
|
|
|
||||||
Tall
|
30
|
|
|
|
|
||||||
Dimer
|
60
|
|
|
|
|
||||||
Comp
|
15
|
|
|
|
|
||||||
|
|
|
|
|
|
||||||
Lights
|
|
|
|
|
|
||||||
|
|
|
|
|
|
||||||
Price list
|
|
|
|
|
|
||||||
|
|
|
|
|
|
||||||
Link to price
|
|
|
|
|
|
||||||
|
|
|
|
|
|
||||||
|
|
|
|
|
|
DIMENSIONS (H. W. D). 1830
x 730 x 860mm
1830 x 880 x 860mm
WEIGHT
280kg
300kg
ELECTRICAL
230VAC 50Hz 5AMP
230VAC 50Hz 5AMP
REFRIGERANT
R404A
R404A
REFRIGERANT CHARGE
450gr
450gr
THERMAL INSULATION
52 mm
52 mm
DOUBLE GLASS DOOR
27mm Gas Filled
27 mm Gas Filled
MINIMUM TEMPERATURE
2° Celsius
2° Celsius
TRAYS
Max of 9
Max of 9
SPIRALS
Max of 72
Max of 90
COINAGE
Executive, MDB
Executive, MDB
COMMUNICATION
Serial, GSM, GPRS
Serial, GSM, GPRS
|